White Rodgers 50a50 405 Manual

Posted on by  admin
White Rodgers 50a50 405 Manual Rating: 4,9/5 7210 reviews

We are dedicated to protecting your order information. Because of this, all personal data that is transmitted through our site is encrypted using SSL or 'Secure Socket Layer' technology which encrypts your order information to avoid the decoding of your information by anyone other than SupplyHouse. At SupplyHouse.com, we are committed to protecting your privacy.

This means that we will not distribute, sell or rent your name or personal information about you to any third party without your permission. For complete safe shopping information, go. Your privacy is of great concern to SupplyHouse. We use the information you provide to process your order and to ensure that your experience on our site is as enjoyable and efficient as possible. Our primary focus and greatest concern is you, our customer. We respect your privacy and therefore do not sell, rent or loan any of your personal information to any third party.

We are committed to protecting your privacy. We use the information that we collect about you to process your orders and to provide a personalized shopping environment. When you purchase products from SupplyHouse.com or register for any SupplyHouse.com services, we automatically place you on our list to receive e-mail updates about special offers, new products, and new services. For our complete privacy policy information, go. A credit card Identification Number is an added safeguard for your credit card purchases. Depending on the type of credit card you use, it is the 3- or 4-digit number printed on the back or front of your credit card.

For most online credit card purchases from us, the Identification Number is required information. MasterCard: Your identification number is the 3-digit number found on the back of your credit card near the signature panel.

Furnace American Standard Gas Furnaces User's Information Manual. White-Rodgers 50A50/50A51 Fault Diagnostics 50A50-405/406 Prior To Revision E4 If. Save white rodgers 50a50-405 to get e-mail alerts and updates on your eBay Feed. + White Rodgers 50A50-405 D340035P01 Furnace Control Board. Or Best Offer. Free Shipping. White Rodgers Trane 50A50-405 Furnace Ignition Control Board CNT1309 D340035P01 See. White Rodgers by Product Types. To locate your free White Rodgers manual, choose a product type below.

Visa: Your identification number is the 3-digit number found on the back of your credit card near the signature panel. American Express: Your identification number is the 4-digit number found on the far right on the front of your credit card. Description for White Rodgers 50A55-843 The 50A55-843 Universal Silicon Carbide Integrated Ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. The Universal Module includes an extensive cross-reference, additional jumper wires, an additional wiring harness and a jumper for Trane applications. The module also has terminals for powering a humidifier and electronic air cleaner. Specifications. Input Voltage: 25 VAC 50/60 Hz.

Maximum Input Current: 25 VAC. 0.45 amp. Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf. Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive). Inducer Relay: 2.2 FLA – 3.5 LRA @ 120 VAC.

Circulator Relay: 14.5 FLA – 25.0 LRA @ 120 VAC. Operating Temperature Range: -40 to +175°F (-40 to +79°C). Humidity Range: 5% to 93% relative humidity Features. Includes flash code diagnostics. Fused to protect low voltage system transformers. Includes mounting hole template. Input Voltage - 25 VAC 50/60 Hz.

Adjustable blower relay. Q&A: Ask the Questions, share answers will this replace my present model50A50-131 Bonnie 2016-01-15 The White-Rodgers 50A55-843 will replace all 50A50 and 50A55 models. Please see the 'Universal Cross Reference' link under 'Resources' on this product's page at: Hope this helps you. 2016-01-15 Yes the sku 50A55-843 is the suggested replacement for the 50A50-131. 2016-05-17 SupplyHouse Staff Does this replace the 50A55-120 in my Lennox-Aire Flo? I have read both yes and no in different places!

My existing board looks nothing like this but that doesn't mean it won't function the same way. Mine has WR printed on it, presumably White Rodgers. On the label it says 50A55-120 Lennox and several other numbers. Usual story.my AC contractor wants $530 but is trying to talk me in to sinking that in to a new system instead.

White Rodgers Model 50a50 405

Steve 2015-06-26 The replacement for the 50A55-120, 56L85. 2015-07-07 Supplyhouse Staff I just installed the 50a55-843 as a replacement for a 50a55-110. Problem was the circulator blower would not run and believed it to be the relay on the control board. Replacement fixed the circulator blower but now the outside unit will not run although was previously running fine.Instructions say there is a second wire from the Y terminal to be connected to the 24 VAC hot side of the compressor contactor. I don't know how to make this connection as isn't the contactor on the outside unit? I assume this second connection isn't to a terminal on the control board. There is a dual fuel circuit board on the outside of the unit with colored wires from thermostat and to furnance and a set to the outside unit.

If I connect the yellow wire to one of the outside unit terminals which one.yellow, white, red, start, etc.nothing here is labeled to the hot side of the compressor contactor. I would appreciate any help Mark 2015-05-09 We do not have technicians on staff it would be best to contact White Rodgers tech support for those answers.

2015-05-11 Supplyhouse Staff Is this a direct replacement for Lennox 56L84 or 56L8401? Jesse 2015-04-28 No it is not, you should call us with the model & serial # of the unit to find the correct part. 2015-04-28 Supplyhouse Staff will this replace 50A50-571 Trane rodger white 2013-11-15 Hi, I used this universal module to replace my furnace module 50-A50-241. According to White Rogers data sheet it should also accommodate 50A50-571.

See the link below. You should be OK to use this one.

White

Follow the wiring instructions. Brochure.pdf 50A55-843 Replaces: 50A50-571 50A55-843 UNIVERSAL SILICON CARBIDE INTEGRATED FURNACE CONTROL Controls Gas Valve, Igniter, Blower, Inducer, Humidifier and Air Cleaner. Replaces Most Trane, York, ICP and Amana White-Rodgers models. Replaces 50A50 and 50A55 7-6265.pdf 2013-11-15 Will this replace 50A50-230 White-Rodgers control for a Luxaire/ Thanks, Ned 2013-06-15 Yes, this is the recommended replacement for the obsolete 50A50-230 control.

2013-06-27 PexSupply Staff Will the 50A55-843 replace my 50A50-230? Ned 2013-06-13 Yes Sent from my Galaxy S®III 2013-06-13 It will. Part 50A55-843 is the replacement for the discontinued 50A50-230. 2013-06-28 PexSupply Staff Does 50A55-843 replace 50A50-405? Peter 2012-11-24 This is probably for a Trane or American Standard I would be careful here you need to call the wholesaler and give them model and serial numbers and they can cross over the proper control 2012-11-24 Yes it does 2012-11-24 Part CNT3797 replaces part 50A50-405. 2012-12-20 PexSupply Staff Will this replace 50A55-438?

(American Standard furnace) Louie 2012-09-07 Yes, it will. 2012-09-11 PexSupply Staff does this replace the 50A50-112 General 90 inter City Products? Does it come with all wiring needed for complete operation?

Craig 2012-03-07 Yes, 50A55-843 is the replacement for the obsolete 50A50-112. This part comes as pictured, but with six different wires. 2012-03-07 PexSupply Staff.

White-Rodgers White-Rodgers 50A50/50A51 Fault Diagnostics Pressure Switch Problem 50A51-495/-506/-507 Two Stage Variable-Speed Systems The induced draft motor will always be energized to high speed. The induced draft motor will be energized to low speed when the Control senses the 1st stage pressure switch contacts have closed. If the 1st stage pressure switch contacts open during a normal 1st stage heating cycle, the gas valve will be de-energized to remove the flame and the induced draft motor will be energized to high speed for 10 minutes.

If the 1st stage pressure switch contacts close during the 10 minute high speed purge, the Control will restart the ignition sequence. If the 1st stage pressure switch contacts remain closed after 10 minutes, the induced draft motor will be energized to low speed and a normal heating operation will continue. If the pressure switch contacts do not close after 10 minutes, the induced draft motor will be energized again to high speed for 10 minutes and the diagnostic LED will begin flashing 3 times to indicate a pressure switch problem. Recycling the induced draft motor will continue as long as a 1st stage call for heat exists and the Control will not go into lockout. The 2nd stage pressure switch fault diagnostic operation is the same as 50A51-405/-505 Controls. CNT2789 13 Thermal Protection Devices At any time during a call for heat, if the Control senses the high temperature limit (and/or aux.

Limit) or flame roll out switch(es) are open, the gas valve is de-energized, the induced draft motor is energized (low speed on 50A51 Controls), and the indoor blower is energized to run on heat speed. On models utilizing fusible link devices, the fusible link is a single use device and must be replaced if it has opened. However, if the temperature the fusible link senses is approaching the trip temperature but does not exceed it, the contacts may open and close intermittently. The Control will initiate another ignition sequence upon the closure of the intermittent fusible link. Flame Sensed With Gas Valve Off At any time the Control senses a flame current signal without a call for heat or when the gas valve is de-energized, the induced draft motor is energized (low speed on 50A51 Controls), and the indoor blower is energized to run on heat speed.1 The Control will go into system lockout and will not reset until this fault is corrected. The diagnostic LED will begin flashing 5 times to indicate the flame sensed with the gas valve de-energized. 1 See Integrated Furnace Control Label or Timing Chart.

White-Rodgers 50A55-571/-474 Self Diagnostic Features 1 OFF 1 2 3 4 DS2 COOL-H PARK PARK LINE-H E17 E28 E27 E13 HEAT-H XFMR-H E16 E18 E14 K2 ON DS1 K1 K3 C4 E4 K5 Y W R G C E4 LINE-N E7 E8 E9 XFMR-N E10 CIR-N E11 K6 FUSE1 E1 Slow Flash – Normal, No Call For Heat Present. Fast Flash – Normal, Call For Heat Present. Continuous On – Internal Control Failure. Diagnostic Indicator Flash Codes: 2 Flashes – System Lockout (Retries or Recycles Exceeded).

3 Flashes – Pressure Switch Stuck Open or Closed. 4 Flashes – Open High Temperature Limit Switch. 5 Flashes – Flame Sensed Without Gas Valve.

6 Flashes – 115 Volt AC Power Reversed. 7 Flashes – Gas Valve Circuit Error. 8 Flashes – Low Flame Sense Signal. See Pages 14 and 15 for Sequence of Operation and Wire Schematic. 1 Fuse only on 474 Model and Dip Switches replace jumpers.

Single Stage 50A50 and 50A55 Sequence of Operation White-Rodgers Integrated Furnace Controls 50A50-405/-406/-471/-472/ -473/-474/-571 and 50A55-571/-474 Models When the disconnect 1 is in the “ON” position, power is applied through the blower door interlock switch 6 to the control line voltage input terminal 8 and out of the control to the primary side of the control transformer “XFMR” 9. The low voltage side of the transformer supplies 24 volts to the control through terminals “TH” o and “TR” i. Control terminal “R”; supplies 24 volts to the “R” terminal of the room thermostat. Once power is applied, the control flashes the LED “ON” for 1 second and performs a self check routine.

Ktm service manual. Sat, 06 Oct 2018 15:41:00. GMT 2009 ktm 200 service manual pdf - We use our own and third party cookies in order to improve your experience and our service. Repair manual KTM 125 / 200. Art No 320588 -E. REPAIR MANUAL. KTM SPORTMOTORCYCLE AG. 5230 Mattighofen. Austria www.ktm.at. KTM EXC models were designed for offroad use only and are only suitable for. Workshop and recorded in the service manual otherwise claims under the warranty shall become void. 125 EXC/EXC SIX DAYS, 200 XC/XC-W/EXC 2009. Sep 21, 2018 - So, 07 Okt 2018 00:30:00. GMT 2009 ktm 200 service manual pdf - free online. 2009 KTM 85 SX, 85 XC. Workshop Service Repair. We use our own and third party cookies in order to improve your experience and our service. With the aid of cookies we analyze the typical use pattern of visitors.

Following the normal system check, the control flashes the LED light once per second continuously (slow flash) while in stand-by. On a call for heat, 24 volts is applied from the thermostat terminal “W” to the “W” terminal; on the control. The control checks and confirms normally closed contacts at the temperature cut out “TCO” f, the auxillary limit (downflow and some upflow/horizontal models), the flame roll-out fuse link (two fuse links are used on downflow and upflow/horizontal models) f and j and normally open contacts of the safety pressure switch “PS” f. With all safety and control switches in their proper position, the control will energize the induced draft motor y and flash the LED light two times per second continuously (fast flash) during a call for heat. When the safety pressure switch “PS” f closes, the control begins the ignition sequence.

The hot surface ignitor y is energized for several seconds (see note) allowing the thermal element to heat up. The control then switches on 24 volts to the gas valve “MV” termi- 14 nals #1 a. The redundant and main solenoids are energized allowing gas flow and main burner ignition.

When flame current is detected by the control through its terminal “FP” k, the 45 second indoor blower motor delay on timing begins. Flame failure response time is set for 2 seconds. After flame has been established for ten seconds, the flame failure response time is reset for 0.7 seconds. If flame current is not sensed by the control k within the trial for ignition period (see note), the redundant and main gas valve solenoids a are de-energized. The control will begin a interpurge cycle and adds additional seconds to the hot surface ignitor warm-up timing (see note). The control energizes the gas valve a for the second attempt to establish main burner ignition.

If flame current is not sensed by the control on the 2nd retry within the trial for ignition period (see note), the control will repeat the previous cycle one additional time before locking out. At the end of the indoor blower delay on time, line voltage is applied at the controls terminal “HEAT” 5 energizing the indoor blower motor at heating fan speed, supplying warm air to the space. When the thermostat is satisfied, the gas valve’s redundant and main solenoids a are de-energized, extinguishing main burner flame. Once the control senses loss of flame current (0.7 sec.) k, the induced draft motor t is de-energized after a five second post purge cycle. The indoor blower motor delay off timing begins. At the completion of the fan delay off timing, the indoor blower motor 5 is de-energized and the cycle is complete.

Note: See Timing Chart for details or Integrated Furnace Control Label.