Olsen Gas Furnace Manual Hds

Posted on by  admin
Olsen Gas Furnace Manual Hds Rating: 4,2/5 2494 reviews

I need a new: 2. My zip code is: Corporate History ECR International was formed in June 1999 as a merger of the Utica Company and Dunkirk Radiator Corporation and named for the founder of both companies, Earle C. DMO Industries was previously known as Duomatic-Olsen. The company changed its name to Olsen Technology Inc. In 2000, ECR International acquired the brand from Olsen's bankrupt parent company, Canadian Manoir Industries Ltd. Product Lines ECR International continues to market oil furnaces and burners under the original DMO Industries brands Olsen and Airco. Today, Olsen/Airco sells oil furnaces and air conditioners.

Sep 26, 2009  I have a 26 year old Duomatic-Olsen furnace. It's a condensing furnace and is about 90% efficient. Single stage burner and only one fan speed. I replaced the blower motor 2 years ago and the combustion blower last year. I am looking to have a new Bryant 355CAV with the Evolution control installed because of the age of my existing furnace. Sep 7, 2015 - The date of production/manufacture or age of Olsen® HVAC equipment can be determined from the serial number located on the data plate.

Olsen Furnace Models

Furnace

Furnaces include lowboy and highboy selections. Units featuring the variable speed motor are capable of reaching up to 85 percent AFUE. Olsen/Airco also offers 13 and 14 SEER air conditioners.

Olsen Gas Furnace Models

. 189 Answers SOURCE: Two wire hookup on the old thermostat tells me that it was set up for heating only. You will most likely need a modern thermostat. But in the meantime try this with the old one.

The two red wires on the furnace are probably Rh & Rc. If so these can be put 'together' on the R terminal on the old stat. The two W's on the new furnace are probably W1 &v W2 This is for first and second stage heat. You can put the two 'together' on the W terminal on the old stat. Do not hook up the greens (blower fan wires). Do not hook up the blue wires (They would go to the Y terminal on a modern stat for airconditioning. Who ever sold you the furnace should have offered you a new thermostat.

Posted on Apr 10, 2009. This going to be little lengthy. The fan can be on from two reasons.

If your thermostat has a fan switch, it will say ON or AUTO. Put it to AUTO.

Turn your thermostat to its lowest setting and wait 3 or 4 minutes. If the fan stays running, the problem is in the furnace. Newer furnaces have big circuit boards that control all its functions. The fan automatically starts after a factory set period of time (about 45 seconds). Try a HARD reset to get all the furnace functions back to normal. Turn your thermostat as low as it will go. Find the breaker or fuse that serves only the furnace.

Olsen Gas Furnace Manual Hds To

Unscrew the fuse or turn off the breaker for a good minute and replace/reset it. If the fan starts right away, the board is probably bad. PC relays often arc together and the entire board will need replacement. If the fan is off, turn your thermostat way up and see if the furnace lights. The fan will probably restart in a minute or so as a normal function, heat or no.

If the furnace does not fire, Let me know and I'll tell you how to check that switch that was replaced. Oct 24, 2013.