Model 17800B Recovery/Recycling/Recharging Unit 3 This manual contains important safety procedures concerning the operation, use and maintenance of this product. 2006 full service repair manual,polaris 2015 ranger 900xp owners manual,robinair acr 2000 troubleshooting manual,a history of palestine from the ottoman. If the operator cannot read this manual, operating instructions and safety precautions must be read and discussed in the operator’s native language. Page 5: Protective Devices Safety Precautions CAUTION: To prevent equipment damage, TO PREVENT CROSS-CONTAMINATION, USE THIS MACHINE WITH R-134A REFRIGERANT ONLY.

  1. Robinair Cooltech Manual
  2. Robinair Parts Manual

Typically this means you have sucked a bunch of air into the internal tank, from a vehicle that had a leak perhaps? Remove the front cover and locate the internal tank. Close the valve on the center hose connection, remove the hose and open the valve slowly and only partially. You should get a good rush of air (not refrigerant).

Try it for about 30 seconds then reset the unit. Repeat if required until unit resets.

Robinair 34700z operator manual

Once reset the unit will purge its self to the correct pressure. No rush of air?, could be a bad high pressure switch, connections on the relay board or a wiring issue. If this doesn't work contact me Posted on Aug 26, 2011. This is a common problem of Robinair 34700Z / 347002K & 347112K series machine.

Weg electric motor wiring diagram manual reset iphone. So don't worry just do the following, with POWER SWITCH OFF: - 1# Open front panel cover and verify the ISV tank is not overfilled. If full, carefully remove refrigerant manually from ISV tank by pressing tank valve. 2# verify if there is high pressure in the ISV tank. Purge excess air from the tank manually. (Open air purge hose from the ISV tank, then carefully press tank valve as needed to blow out excess pressure from the ISV tank) After doing all above stapes and your problem still exist then replace air purge solenoid (Air purge solenoid located near the ISV tank and fixed with automatic air purge device). Hope this will solve your problem, if so please vote for it for farther help! Good luck May 17, 2011.

If your machine is one of the bellow Model:- Robinair 34700Z / 347002K & 347112K series. Just do the following, with POWER SWITCH OFF: - 1# Open front panel cover and verify the ISV tank is not overfilled.

If full, carefully remove refrigerant manually from ISV tank by pressing tank valve. 2# verify if there is high pressure in the ISV tank. Purge excess air from the tank manually. (Open air purge hose from the ISV tank, then carefully press tank valve as needed to blow out excess pressure from the ISV tank) After doing all above stapes and your problem still exist then replace air purge solenoid (Air purge solenoid located near the ISV tank and fixed with automatic air purge device). Hope this will solve your problem, if so please vote for it for farther help!

Robinair Cooltech Manual

Good luck May 13, 2011. This is a common problrm of Robinair 34700Z / 347002k & 347112k series machine.so don't worry just do the following:- 1# Verify the ISV tank is not overfilled.if full,remove refrigerant manually from tank. 2# Verify if there is high pressure in the tank.Purge excess air from the tank manually.( Open air purge hose from the tank,then press tank valve as needed) 3#Check the high pressure switch for proper operation,if not then replace high pressure switch.Hope this will solve your problem, if so please vot for it Jan 04, 2011. This is a common problem of Robinair 34700Z / 347002k & 347112k series machine.so don't worry just check the following:- 1# Verify the ISV tank is not overfilled.if full,remove some refrigerant manually from tank. 2# Purge excess air from the tank manually.( Open air purge hose from the tank,then press tank valve as needed to purge air from the tank) 3#Check the air purge solenoid & High pressure switch for proper operation.Hope this will solve your problem, Best of luck & vote for my solution Aug 21, 2010. This is a common problrm of Robinair 34700Z / 347002k & 347112k series machine.so don't worry just do the following:- 1# Verify the ISV tank is not overfilled.if full,remove refrigerant manually from tank. 2# Verify if there is high pressure in the tank.Purge excess air from the tank manually.( Open air purge hose from the tank,then press tank valve as needed) 3#Check the high pressure switch for proper operation,if not then replace high pressure switch.Hope this will solve your problem May 27, 2010.

Robinair Parts Manual

This is a common problrm of Robinair 34700Z / 347002k & 347112k series machine.so don't worry just do the following:- 1# Verify the ISV tank is not overfilled.if full,remove refrigerant manually from tank. 2# Verify if there is high pressure in the tank.Purge excess air from the tank manually.( Open air purge hose from the tank,then press tank valve as needed) 3#Check the high pressure switch for proper operation,if not then replace high pressure switch.Hope this will solve your problem Feb 05, 2010. This is a common problrm of Robinair 34700Z / 347002k & 347112k series machine.so don't worry just do the following:- 1# Verify the ISV tank is not overfilled.if full,remove refrigerant manually from tank. 2# Verify if there is high pressure in the tank.Purge excess air from the tank manually.( Open air purge hose from the tank,then press tank valve as needed) 3#Check the high pressure switch for proper operation,if not then replace high pressure switch.Hope this will solve your problem Aug 17, 2009.